ZEMCH 2012 International Conference Proceedings - page 377

S p o n t a n e o u s A r c h i t e c t u r e a n d E n e r g e t i c S u s t a i n a b i l i t y
367
COVERING ROOF
STRATIGRAFY (from bottom)
Thickness
cm
26
Surface weight
kg/m²
380,300
Plaster of lime
Thermal capacity
kJ/(m²·K)
77,82
Cane
Thermal resistance
m²·K/W
1,425
Dry sand
Thermal trasmittance
W/(m²·K)
0,702
Cast of lime, water and volcanic inert Periodic thermal trasmittance
W/(m²·K)
0,116
Insulation
Attenuation
0,165
Exterior finish
temperature offset
[h]
-8,53
MASONRY VOULT
STRATIGRAFY (from bottom)
Thickness
cm
35
Surface weight
kg/m²
617,400
Plaster of lime
Thermal capacity
kJ/(m²·K)
78,00
Lavic stones
Thermal resistance
m²·K/W
1,236
Cast of lime, water and volcanic inert Thermal trasmittance
W/(m²·K)
0,809
Insulation
Periodic thermal trasmittance
W/(m²·K)
0,145
Exterior finish
Attenuation
0,179
temperature offset
[h]
-9,3
EXTERNAL VERTICAL MASONRY
STRATIGRAFY (from extern)
Thickness
cm
70
Surface weight
kg/m²
1320,000
Plaster of lime
Thermal capacity
kJ/(m²·K)
115,08
Lavic stones and lime
Thermal resistance
m²·K/W
0,502
Plaster of lime
Thermal trasmittance
W/(m²·K)
1,992
Periodic thermal trasmittance
W/(m²·K)
0,105
Attenuation
0,053
temperature offset
[h]
-15,25
Figure 7: thermotecnical parameters.
Thanks
A special thanks to Fiorenza D’Urso, Aldo Siragusa, Walter Pettinato and Agatino
Bonanno who have made the drawings, under my guidance and to Ing. Massimo De
Tommaso, who helped me to calculate the Thermotechnical parameters.
References
PERRICONE, M., OLIVA, A., 1995, ‘Tecniche costruttive tradizionali negli insediamenti
abitativi di striomboli’ Proceedings of the International symposium: The prroject in the
space of memory: signs, ideas and future development. Naples, pp. 527-540.
POLVERINO, F., 1998, ‘Ischia: architettura e terremoto’. Clean Edizioni, Neaples.
POLVERINO, F.., 1999, ‘Tra lastrici e terrazzi’. CUEN s.r.l., Neaples.
TROVATO, C. S., TROPEA, G., PICCITTO, G., 1985-2002, ‘Vocabolario siciliano’,
centro di studi filologici e linguistici siciliani, Palermo.
UNESCO, 2000, World Heritage List, Aeolian islands, <
/908>.
EFFICIENCY RESEARCH GROUP, Politecnico di Milano, 2005-2007, Passive-On
project, <
>.
EOLIE.IT ASS., Web site, 2004-2010, climatic conditions <
>.
MARGANI, G., 2010, ‘Murature massive e comfort sostenibile in clima mediterraneo’,
Costruire in Laterizio, 137, pp. 65-71.